Independent qualification testing of Teledyne Marine’s TCSC4211-04 subsea Ethernet cable by Norwegian subsea technology company Ixys AS has demonstrated the assembly’s ability to maintain electrical and Ethernet performance under high-pressure conditions exceeding its rated operating pressure.
Cable reliability is a critical consideration for deepwater operations, where component failures can result in project delays, unscheduled vessel time, and complex offshore interventions. When evaluating alternatives to an existing cable supplier, Ixys sought to verify cable performance through practical testing rather than relying solely on technical specifications.
Following discussions with Teledyne Marine, Ixys obtained a cable sample and established an independent qualification program using its own connectors, equipment, test procedures, and acceptance criteria.
Subsea Cable Assembly Configuration
Drawing on its experience in the design and manufacture of subsea systems and cable assemblies, Ixys constructed a test assembly incorporating the Teledyne TCSC4211-04 Cat5e subsea Ethernet cable and two Scorpion subsea connectors.
The assembly was manufactured using Ixys’ own termination and assembly processes, with a cable length and configuration representative of its subsea applications.
The qualification program covered electrical continuity, contact resistance, insulation resistance, Ethernet performance, and hyperbaric pressure exposure.
Electrical Continuity and Insulation Resistance
Resistance measurements were taken across all conductor paths before, during, and after hyperbaric exposure to assess electrical integrity throughout the pressure cycle.
All conductors remained within Ixys’ acceptance limits, including at full test pressure. No unstable contacts, open circuits, or excessive variations in resistance were recorded.
Insulation resistance measurements also exceeded the minimum acceptance threshold of 550 MΩ (0.55 GΩ). Recorded values ranged from approximately 1.7 GΩ to more than 5.2 GΩ, demonstrating dielectric integrity and resistance to electrical leakage under the tested conditions.
Ethernet Performance Validation
Data transmission capabilities were assessed through wire mapping validation, Ethernet signal integrity testing, and Gigabit Ethernet qualification.
The assembly successfully completed each assessment, confirming its ability to support high-speed Ethernet communications while maintaining performance under the pressures applied during qualification.
Hyperbaric Testing at 440 Bar
Ixys subjected the cable assembly to an extended hyperbaric test at 440 bar (6,382 psi), equivalent to 110% of its rated operating pressure.
Electrical and Ethernet performance were maintained throughout the full pressure cycle, with the assembly meeting all applicable acceptance criteria.
Following completion of the qualification program, Ixys reported that every tested parameter was well within its acceptance limits. The use of its own connectors, assembly methods, equipment, and testing procedures provided independent validation of the cable’s performance within a representative subsea assembly.
Supporting Subsea Supply Chain Resilience
Successful qualification prompted further discussions regarding the supply of larger production lengths for field use, moving the evaluation beyond the initial laboratory sample.
In addition to establishing the cable’s technical suitability against Ixys’ requirements, the results highlighted the potential for Teledyne Marine to provide an alternative source of supply during periods of supplier disruption.
Independent component qualification can support both engineering and procurement decisions by addressing technical performance and sourcing risks. In the case of the TCSC4211-04, the testing demonstrated stable electrical performance, insulation integrity, and Gigabit Ethernet capability under demanding hyperbaric conditions.
These findings provide Ixys with independently established performance data to support component selection for subsea systems, where cable reliability contributes to operational uptime, project success, and mission continuity.
Read How Independent Testing Validated Teledyne’s Subsea Ethernet Cable on the Teledyne Marine website.